Fig. 35: Identifying A/C Diode A
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there current flow in only one direction?
YES : An open in No. A8 (7.5 A) fuse circuit wire. REPLACE THE UNDER-HOOD FUSE/RELAY
BOX .
NO : Replace A/C diode A.
A/C DIAGNOSTIC PROCESS
When a customer presents A/C concern, do the following procedure to identify the cause of the problem.
1. Confirm the type of concern.
ο¬
ο¬
If a customer presents about A/C noise problem, do the A/C System Noise Check .
If a customer presents about A/C performance problem, go to step 2.
2. Do the A/C System Inspection and repair any problems. If no problems are found, then go to step 3.
3. Recover the refrigerant from the A/C system See A/C REFRIGERANT RECOVERY , A/C
SYSTEM CHARGING or A/C System Evacuation and measure the refrigerant charge from the A/C
system using a recovery/recycling/charging station that meets SAE J2788 standards.
ο¬
If the refrigerant charge is within specifications, evacuate See A/C REFRIGERANT
RECOVERY , A/C SYSTEM CHARGING or A/C System Evacuation and recharge the
system See A/C REFRIGERANT RECOVERY , A/C SYSTEM CHARGING or A/C System
Evacuation . Then go to step 4.
ο¬
ο¬
If the refrigerant charge is significantly under specifications, then go to step 5.
If the refrigerant charge is significantly over specifications, evacuate See A/C REFRIGERANT
RECOVERY , A/C SYSTEM CHARGING or A/C System Evacuation and recharge the
system See A/C REFRIGERANT RECOVERY , A/C SYSTEM CHARGING or A/C System
Evacuation . Then go to step 7.
4. Do the A/C System Test .
If vent temperature or suction/discharge pressures are not within specifications, diagnose and repair
the A/C system as needed. Then go to step 6.
ο¬
ο¬
If no problems are found, the A/C system is operating as designed and the A/C diagnostic process
is complete.
5. Do the REFRIGERANT LEAK CHECK .
ο¬
If any leaks are found, repair the A/C system as needed. Then go to step 6.
If no leaks are found, go to step 7.
ο¬
6. Evacuate See A/C REFRIGERANT RECOVERY , A/C SYSTEM CHARGING or A/C System
Evacuation and recharge the system See A/C REFRIGERANT RECOVERY , A/C SYSTEM
CHARGING or A/C System Evacuation . Then go to step 7.
7. Do the A/C System Test to confirm your repairs.
ο¬
If vent temperature or suction/discharge pressures are within specifications, the repair is confirmed
and the A/C diagnostic process is complete.
ο¬
If vent temperature or suction/discharge pressures are not within specifications, a problem may still
exist. Return to step 1 and recheck your test procedures.