Honda CR-V Heating, Ventilation & Air Conditioning Troubleshooting ➜ A/C Condenser Fan High Speed Circuit Troubleshooting (Manual A/C)

Fig. 29: Identifying A/C Diode A  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
Is there current flow in only one direction?  
YES : An open in the No. A8 (7.5 A) fuse circuit wire. REPLACE THE UNDER-HOOD  
FUSE/RELAY BOX .  
NO : Replace A/C diode A.  
A/C CONDENSER FAN HIGH SPEED CIRCUIT TROUBLESHOOTING  
(MANUAL A/C)  
Fig. 30: A/C Condenser Fan High Speed Circuit Troubleshooting Flow Chart  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
NOTE:  

Do not use this troubleshooting procedure if the A/C compressor is  
inoperative. Refer to the symptom troubleshooting index.  


If A/C refrigerant pressure is abnormal, the radiator and A/C condenser  
fans are controlled based only on engine coolant temperature.  
Before doing symptom troubleshooting, check for PGM-FI DTCs See HOW  
TO TROUBLESHOOT THE A/T SYSTEM or HOW TO TROUBLESHOOT THE  
FUEL AND EMISSIONS SYSTEMS .  
1. Fuse check:  
ο‚‘
1. Check the following fuses.  
Fuse No. A2-10 (20 A)  
Location Under-hood fuse/relay box  
Fuse No. A8 (7.5 A)  
Location Under-hood fuse/relay box  
Are the fuses OK?  
YES : Go to step 2.  
NO : Replace the fuse(s), and recheck. If the fuse(s) blow again, check for a short in the No. A2-10 (20  
A) fuse and/or the No. A8 (7.5 A) fuse circuit(s).  
2. A/C condenser fan relay check:  
ο‚‘
1. Remove the A/C condenser fan relay from the under-hood fuse/relay box, and TEST IT .  
Is the relay OK?  
YES : Go to step 3.  
NO : Replace the A/C condenser fan relay.  
3. Open wire check (+B SUB FAN line):  
ο‚‘
1. Measure the voltage between test points 1 and 2.  
Test condition IG LOCK (0)  
A/C condenser fan relay: disconnected  
Test circuit +B SUB FAN  
Test point 1 A/C condenser fan relay 4P socket No. 1  
Test point 2 Body ground  
Fig. 31: Measuring Voltage Between Test Points 1 And 2  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
Is there battery voltage?  
YES : The +B SUB FAN wire is OK. Go to step 4.  
NO : An open in the +B SUB FAN wire. REPLACE THE UNDER-HOOD FUSE/RELAY BOX .  
4. SUB FAN MOTOR line check:  
ο‚‘
1. Connect terminals A and B with a jumper wire.  
Terminal A A/C condenser fan relay 4P socket No. 1  
Terminal B A/C condenser fan relay 4P socket No. 2 (YEL)  
Fig. 32: Connecting Terminals A And B With Jumper Wire  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
Does the A/C condenser fan run on high?  
YES : The SUB FAN MOTOR wire is OK. Go to step 5.  
NO : Repair an open in the wire between the A/C condenser fan relay and the A/C condenser fan motor.  
5. A/C condenser fan relay coil side power circuit check:  
ο‚‘
1. Disconnect the jumper wire.  
ο‚‘
2. Turn the ignition switch to ON (II).  
ο‚‘
3. Measure the voltage between test points 1 and 2.  
Test condition IG ON (II)  
A/C condenser fan relay: disconnected  
Test circuit SUB FAN DIODE-  
Test point 1 A/C condenser fan relay 4P socket No. 3 (WHT)  
Test point 2 Body ground  
Fig. 33: Measuring Voltage Between Test Points 1 And 2  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
Is there battery voltage?  
YES : The No. A8 (7.5 A) fuse circuit wire is OK. Go to step 6.  
NO : Go to step 7.  
6. Open wire check (FAN HI SIGNAL line):  
ο‚‘
ο‚‘
ο‚‘
1. Turn the ignition switch to LOCK (0).  
2. Reinstall the A/C condenser fan relay.  
3. Jump the SCS line with the HDS.  
NOTE:  
This step must be done to protect the PCM from damage.  
ο‚‘
ο‚‘
4. Disconnect the following connector.  
PCM connector A (49P)  
5. Connect terminals A and B with a jumper wire.  
Terminal A PCM connector A (49P) No. 16 (GRY)  
Terminal B Body ground  
Terminal A PCM connector A (49P) No. 20 (WHT)  
Terminal B Body ground  
Fig. 34: Connecting Terminals A And B Using Jumper Wire  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
ο‚‘
6. Turn the ignition switch to ON (II).  
Does the A/C condenser fan run on high?  
YES : Update the PCM See PCM REMOVAL AND INSTALLATION or PCM UPDATE if it does  
not have the latest software, or substitute a known-good PCM See PCM REMOVAL AND  
INSTALLATION or PCM UPDATE , and recheck.  
NO : Repair an open in the wire between the A/C condenser fan relay and the PCM.  
7. A/C diode A check:  
ο‚‘
1. Turn the ignition switch to LOCK (0).  
ο‚‘
2. Using the diode setting on a DVOM, check for current flow in both directions between A/C  
diode A terminals No. 1 and No. 2.  
Fig. 35: Identifying A/C Diode A  
Courtesy of AMERICAN HONDA MOTOR CO., INC.  
Is there current flow in only one direction?  
YES : An open in No. A8 (7.5 A) fuse circuit wire. REPLACE THE UNDER-HOOD FUSE/RELAY  
BOX .  
NO : Replace A/C diode A.  
A/C DIAGNOSTIC PROCESS  
When a customer presents A/C concern, do the following procedure to identify the cause of the problem.  
1. Confirm the type of concern.  


If a customer presents about A/C noise problem, do the A/C System Noise Check .  
If a customer presents about A/C performance problem, go to step 2.  
2. Do the A/C System Inspection and repair any problems. If no problems are found, then go to step 3.  
3. Recover the refrigerant from the A/C system See A/C REFRIGERANT RECOVERY , A/C  
SYSTEM CHARGING or A/C System Evacuation and measure the refrigerant charge from the A/C  
system using a recovery/recycling/charging station that meets SAE J2788 standards.  

If the refrigerant charge is within specifications, evacuate See A/C REFRIGERANT  
RECOVERY , A/C SYSTEM CHARGING or A/C System Evacuation and recharge the  
system See A/C REFRIGERANT RECOVERY , A/C SYSTEM CHARGING or A/C System  
Evacuation . Then go to step 4.  


If the refrigerant charge is significantly under specifications, then go to step 5.  
If the refrigerant charge is significantly over specifications, evacuate See A/C REFRIGERANT  
RECOVERY , A/C SYSTEM CHARGING or A/C System Evacuation and recharge the  
system See A/C REFRIGERANT RECOVERY , A/C SYSTEM CHARGING or A/C System  
Evacuation . Then go to step 7.  
4. Do the A/C System Test .  
If vent temperature or suction/discharge pressures are not within specifications, diagnose and repair  
the A/C system as needed. Then go to step 6.  
